Infant Incubator SKIN / MANUAL, Double Walled Mounted on Trolley MODEL: INC 1002B
Infant Incubator Skin/Manual,Double Walled Mounted on Trolley INC 1002B Model
Mechanical Specification
Mechanical Specification For Infant Incubator Model INC 1002B
Acrylic double walled canopy with front loading & six elbow operated port holes
Mechanical Specification For Infant Incubator Model INC 1002B
Sliding acrylic baby tray
Mechanical Specification For Infant Incubator Model INC 1002B
Facility to take X-ray
Mechanical Specification For Infant Incubator Model INC 1002B
Two lower shelves to keep essential things for baby
Mechanical Specification For Infant Incubator Model INC 1002B
Mounted on heavy duty castors
Mechanical Specification For Infant Incubator Model INC 1002B
Stainless steel blower sub assembly
Mechanical Specification For Infant Incubator Model INC 1002B
Inlets for oxygen, IV tubings, etc.
Mechanical Specification For Infant Incubator Model INC 1002B
Humidity tray & humidity indicator
Mechanical Specification For Infant Incubator Model INC 1002B
External head up/down positioning facility

Micro Computer Temperature Controller
Micro Computer Temperature Controller
Provides thermal regulation with highest degree of accuracy
Micro Computer Temperature Controller
User friendly feather touch control
Micro Computer Temperature Controller
Skin control: 34 to 38°C
Micro Computer Temperature Controller
Resolution : 0.1°C
Micro Computer Temperature Controller
Accuracy: ± 0.2°C within set temp.
Micro Computer Temperature Controller
Safety alarms along with high temp. Cutoff.
Micro Computer Temperature Controller
Power source: 230 volts ± 10%, 50 Hz.





For Further Details Contact:
Zeal Medical Pvt. Ltd.
4/19 -A, Piramal Indl. Est., S. V. Road, Goregaon (W),
Mumbai 400062. India
Tel:. 91 22 2876 02 74
TeleFax:. 91 22 2876 19 05
Email:. zealmedi@bom3.vsnl.net.in
Website:. http://www.zealmedical.com

Pediatric Oncall does not endorse any specific product, service, or treatment.
levioza
Levioza
Login
levioza
User Name :
Password :
 
 
 
 
 
Educational Section
 
Disclaimer:
The information given by www.pediatriconcall.com is provided by medical and paramedical & Health providers voluntarily for display & is meant only for informational purpose. The site does not guarantee the accuracy or authenticity of the information. Use of any information is solely at the user's own risk. The appearance of advertisement or product information in the various section in the website does not constitute an endorsement or approval by Pediatric Oncall of the quality or value of the said product or of claims made by its manufacturer.
 
copyright ©2011 website design & development by Levioza
Follow Us
Follow us on :
Folllow Us